VIDEOMED ZAK?AD ELEKTRONICZNY
14Pages

{{requestButtons}}

Catalog excerpts

VIDEOMED ZAK?AD ELEKTRONICZNY - 1

Audiometer AUDIO 4002 Audiometer AUDIO 4002 is a two channel clinical audiometer Class 1. The device has a wide range of applications in diagnosis and in clinical researches. Perfect for the diagnosis of both small and large hearing deficit. The maximum sound level is 130 dBHL. Frequency range from 125 Hz to 12000 Hz. Ability to perform SISI tests. Indispensable for hospitals, clinics, ENT clinics and hearing care professionals. Works with computers, PC / Laptop, with USB 2.0 port, the software Effetha. Audiometer is working on operating systems Windows XP / VISTA / 7 (versions 32 and 64 bit). Outputs: left/right AC, BC Frequences AC [Hz]: 125 - 12k, BC [Hz]: 250 – 8k Level (AC): -10dBHL ~ 130dBHL Level (BC): -10dBHL ~ 85dBHL Level (mask.): to 90dBHL Level (FF): to 90dB Step: 5dB Tone: pure, pulsed, modulated Masking: narrowband Tests: manual,HW, SISI, speech Communication: in-built microphone talk-forward Dimensions: 105 x 180 x 55 mm Weight: 240g (without converters) STANDARDS Safety: EN60601-1 EMC: EN60601-1 Audiometry: EN60645-1/ANSI S3.6, Type 2 Speech audiometry: EN 60645-2/ANSI S3.6 Type B or B-E Medical sign: CE 0044 TÜV NORD Standard equipment: • Audiometric headphones with anti-noise covers • Bone headphone • Effetha software • Patient's button • Microphone to communicate with the patient • Transport bag • USC wire • Free field column • Westrs' word and numeric tests Manufacturer: VIDEOMED ZAKŁAD ELEKTRONICZNY ul. Klonowa 18 58-310 Szczawno-Zdrój Poland tel. +48 74 843 81 09 fax +48 74 840 17 33 web: http://www.videomed.eu e-mail: handlowy@videomed.eu

Open the catalog to page 1
VIDEOMED ZAK?AD ELEKTRONICZNY - 2

SMART Audiometers SMART audiometers are miniature digital devices for the diagnosis of hearing loss. Indispensable for hospitals, clinics, ENT consutation rooms and hearing care professionals. In conjunction with a laptop it is the perfect kit for house calls or examination of patients that can't be moved. Energy-saving design - power consumption via computer USB port is only 2W. Ideal for the diagnosis of both small and large hearing loss. The maximum sound level of 130 dBHL (SMART 130). Co-operation with a PC / Laptop with a USB 2.0 port, Effetha 2 software and Windows XP / VISTA / 7, 32...

Open the catalog to page 2
VIDEOMED ZAK?AD ELEKTRONICZNY - 3

IMPORTANT TASKS REQUIRE SMART SOLUTIONS Ultra 130 is a small digital diagnostic audiometer. Ultra 130 is made to make measurements with the test booth becasue of the standard plugs - jack. Ultra 130 can also be used as an portable device because the device still is very small. Ultra 130 has all necessary equipment to conduct the diagnos- tics hearing loss tests, like air and bone conductors, FF speaker, speach audiometry option, masking option, SISI and ABLB tests. Ultra 130 audiometer is a complex device made for the hearing aids acousticians and also for ENT doctors. It is easy to operate...

Open the catalog to page 3
VIDEOMED ZAK?AD ELEKTRONICZNY - 4

I IITDA IMPORTANT TASKS REQUIRE Effetha is currently available in English and Polish languages. If you are inter- ested in your own language it can be easily prepared thanks to universal char- acter of our software. In such case please contact us. All text is stored with UTF-8 encoding, making the software independent of specific language. This software also works with Effetha Video so it is possible to compare data of patients from the video examination. It is user friendly and it is possible to learn quickly how does it works. Patients can also quickly learn how to cooperate with...

Open the catalog to page 4
VIDEOMED ZAK?AD ELEKTRONICZNY - 5

Ul TD A 4"5 f\ IMPORTANT TASKS REQUIRE Frrst name: John Second name: Last name: Smith Postal code: Company name: Cell number Home number Office number Save change? Noise dampening VIDEOMED ELECTRONIC WORKS POLAND www.videomed.eu SMART SOLUTIONS

Open the catalog to page 5
VIDEOMED ZAK?AD ELEKTRONICZNY - 6

IMPORTANT TASKS REQUIRE SMART SOLUTIONS Sound level ranges per sound emission type VIDEOMED ELECTRONIC WORKS POLAND www.videomed.eu SMART SOLUTIONS

Open the catalog to page 6
VIDEOMED ZAK?AD ELEKTRONICZNY - 7

IMPORTANT TASKS REQUIRE SMART SOLUTIONS Included parts Optional parts Patient response button Builtin microphone Operation manual Diagnostic software Effetha 2 EARTone5A Audiometric insert phones Talkback Microphone VIDEOMED NOAH 4.x module Carrying case * With VMware for Linux ** Supported languages: English, Polish - please contact us if you need support for your langauge version *** AS4 Active Spearker powered from USB or external supply 5V. Maximum power when VIDEOMED ELECTRONIC WORKS POLAND www.videomed.eu SMART SOLUTIONS

Open the catalog to page 7
VIDEOMED ZAK?AD ELEKTRONICZNY - 8

IMPORTANT TASKS REQUIRE SMART SOLUTIONS IjSmart is an excellent digital clinic audiometer with high frequency up to 20kHz. Unmatched quality of sound delivered by this device allows for perfect simulation of real-world sound situations. It integrates with a PC to provide a comprehensive and pro-active audiometric facility. The device is ideal for both: stationary hearing loss measurement and hearing loss measurement next to the patient's bed. Double playback-independent channels of uSmart enables playback of two different sounds in the left and right ear. It can also mask the noise from the...

Open the catalog to page 8
VIDEOMED ZAK?AD ELEKTRONICZNY - 9

IMPORTANT TASKS REQUIRE SMART SOLUTIONS Effetha is currently available in English and Polish languages. prepared thanks to universal such case please contact us. All text is stored with UTF-8 encoding, making the software guage. This software also works with Effetha Video so it is possible to compare data of patients from the video exami- @ 2011 Videomed. Ml rights reserved Test election Foil Vntofsnl Audi&mtttr Speech ABLB SIS1 L^rtgcnbect audiometrj test test teil Measurement selection Maskrng Binaural 3h(c;hold Most comfortable Uncomfortable level level Secondary channel mode VIDEOMED...

Open the catalog to page 9
VIDEOMED ZAK?AD ELEKTRONICZNY - 10

IMPORTANT TASKS REQUIRE SMART SOLUTIONS It is user friendly and it is possible to learn quickly how does it works. Patients can also quickly learn how to cooperate with diagnostics. Software is protected by password which will prevent from unauthorized use. Effetha works with Windows 7 (32/64bit), Vista and XP operating systems. First name: John Second name Last name: Smith Postal code: Company name: Cell number Home number: Office number: Noise dampening

Open the catalog to page 10

All Videomed catalogs and technical brochures

  1. C3 multi

    2 Pages

  2. Otoscillo

    1 Pages

  3. VIDEOSMART.

    4 Pages

  4. smart

    8 Pages

  5. ULTRA 130

    8 Pages